Publication Date:
2020
abstract:
Three-leaf brick masonry wall is a typical technique in historical buildings. Sensitivity of three-leaf brick masonry wall to core mechanical characteristics and interface between layers is studied by reference to an experimental campaign. Experimental activities were performed on three-leaf masonry panel under compressive loads and is used to identify mechanical characteristic of three-leaf masonry wall and calibrate a 2D plain strain model (without and with interfaces between layers) for cross section of panel. A parametric analysis on inner core and interface between layers mechanical characteristic sensitivity is proposed. Numerical modeling results are presented and discussed in comparison with experimental data.
Iris type:
1.1 Articolo su Rivista
Keywords:
Three-leaf walls
Brick masonry
Interface
Compression tests
FEM simulation
Experimental tests
List of contributors:
de Carvalho Bello, Claudia Brito; Boscato, Giosuè; Meroi, Emilio; Cecchi, Antonella
Published in: