Performance optimization of a demand controlled ventilation system by long term monitoring

Articolo
Data di Pubblicazione:
2018
Abstract:
The thermo-hygrometric treatment related to the air change in buildings requires a relevant quota of the total energy demand of HVAC systems, especially when the ventilation demand is significant. A correct energy saving strategy therefore should always focus on the use of suitable techniques to reduce this energy consumption. As proved by the modern theories on comfort, less strict values can be accepted for the internal humidity set points without compromising indoor comfort conditions. In addition, Demand Controlled Ventilation (DCV) gives the opportunity to reduce energy requirements. This paper investigates the opportunities offered by the installation of a DCV system and a Building Management System (BMS) able to perform long term monitoring of the HVAC system in a real case study. This refers to a historic building in Venice in the area of the harbour and recently transformed into a modern university facility. Starting from the experimental data recorded by BMS, an optimization of the control strategies and simple tuning actions of the DCV controller were possible. Results validate the use of more flexible set points of indoor relative humidity and long term on-line tuning even in absence of self-learning control systems, as well as they highlight the achievement of remarkable energy savings thanks to these actions. The research demonstrates the fundamental contribution of successive control performance assessments by long term monitoring to individuate possible weaknesses in DCV system management.
Tipologia CRIS:
1.1 Articolo su Rivista
Keywords:
Indoor air quality, Demand side management, Demand controlled ventilation, Energy retrofit, Long term monitoring.
Elenco autori:
Schibuola, Luigi; Scarpa, Massimiliano; Tambani, Chiara
Autori di Ateneo:
SCARPA MASSIMILIANO
SCHIBUOLA LUIGI
TAMBANI CHIARA
Link alla scheda completa:
https://air.iuav.it/handle/11578/277195
Pubblicato in:
ENERGY AND BUILDINGS
Journal