Set-up and calibration by experimental data of a numerical model for the estimation of solar factor and Ug-value of building integrated photovoltaic systems
Articolo
Data di Pubblicazione:
2015
Abstract:
The acronym BIPV (Building Integrated Photovoltaics) refers to the installation of photovoltaic systems which, in addition to convert solar energy into electrical energy, have a high level of architectonical integration with the built environment, becoming a real architectural cladding to be installed over the buildings in place of traditional envelope systems. Many typologies of BIPV have been developed, however their thermal characteristics such as g and Ug-value are not well evaluated and require more detailed analyses considering that they could replace large extension of traditional building envelope. A first approach to address this problem is proposed in this work. A mathematical model based on a finite differences scheme for the estimation of the thermal parameters g and Ug-value has been developed and tuned using experimental value measured on sample BIPV with a Hot Plate and a Solar Calorimeter. The results of the model show that the introduction of solar cells in a laminated glass or in a double glass leads to a reduction of energy parameters modifying winter and summer energy balance of the building system.
Tipologia CRIS:
1.1 Articolo su Rivista
Keywords:
BIPV; Glazing systems; Solar factor; Ug-value; Energy modeling
Elenco autori:
Mazzali, Ugo; Ruggeri, Paolo; Zinzi, M.; Peron, Fabio; Romagnoni, Piercarlo; Daneo, A.
Link alla scheda completa:
Link al Full Text:
Pubblicato in: