Data di Pubblicazione:
2014
Abstract:
In this paper different configurations of an open-space office located in Rome has been simulated with EnergyPlus 8 to compare
the performance of outdoor and indoor shading devices concerning the thermal and visual comfort and the overall primary energy
use. The standard PMV indices [1] have been calculated considering also the effect of the diffuse and beam solar radiation
directly reaching the occupants through the windows. Although the use of shades always improves the thermal comfort, the
energy demand could increase as an effect of the internal position of shades in combination with particular orientations and
glazing types.
the performance of outdoor and indoor shading devices concerning the thermal and visual comfort and the overall primary energy
use. The standard PMV indices [1] have been calculated considering also the effect of the diffuse and beam solar radiation
directly reaching the occupants through the windows. Although the use of shades always improves the thermal comfort, the
energy demand could increase as an effect of the internal position of shades in combination with particular orientations and
glazing types.
Tipologia CRIS:
1.1 Articolo su Rivista
Elenco autori:
Anna, Atzeri; Cappelletti, Francesca; Andrea, Gasparella
Link alla scheda completa:
Pubblicato in: